        Hot Spring Hi-Limit Sensor 79005 (Replaces 39204)      
    
    
        £32.50  
         
            
            In stock 
        
        
        Less than 5 left!    
  
        
Replacement Hi-Limit Sensor for Hot Spring Spas 
Part numbers 79005 and replaces 39024 
Official Hot Spring Part 
Comes with replacement O-ring 
See list of suitable models on the full description.  
  
 
 
    Want it Wednesday, 5 November ? Order it within 0  hours   0  minutes   and choose Next Day Delivery  at checkout
     
                
                                                        
                
                    
        Hot Spring OEM High-limit thermistor plugs into the motherboard, which is inside the IQ 2000 Box. If water temperature of spa reaches 46 degrees Celcius or over, this sensor will shut heater down in order to prevent damage or injury.
79005 replaces older style #39204 sensor.
Comes with replacement O-ring for seal.
See diagnostics here 
79005 High Limit Sensor is for the following Hot Spring models:
Make  
Model  
Date Range  
 
Hot Spring 
Grandee 
2001-Current 
 
Hot Spring 
Vista  
2004-2013 
 
Hot Spring 
Envoy 
2004-Current 
 
Hot Spring 
Vanguard 
2001-Current 
 
Hot Spring 
Grandee NXT 
2014-Current 
 
Hot Spring 
Envoy NXT 
2014-Current 
 
Hot Spring 
Jetsetter NXT 
2014-Current 
 
Hot Spring 
Prodigy 
2001-Current 
 
Hot Spring 
Sovereign 
2001-Current 
 
Hot Spring 
Accolade 
2005-2006 
 
Hot Spring 
Aria 
2007-Current 
 
Hot Spring 
Highlife ILE 
2003 
 
Tiger River 
Bengal 
2001-2010 
 
Tiger River 
Siberian 
2001-2004 
 
Tiger River 
Caspian 
2003-2010 
 
Tiger River 
Sumatran 
2001-2010 
 
Tiger River 
Bengal Model MM 
2005-2010 
 
Limelight 
Bolt 
2012-2018 
 
Limelight 
Pulse 
2008-Current 
 
Limelight 
Gleam 
2013-2018 
 
Limelight 
Flair 
2008-Current 
 
Limelight 
Glow 
2008-2018 
 
Limelight  
Beam 
2018-Current 
 
Limelight 
Flash 
2018-Current 
 
Limelight 
Prism 
2018-Current 
 
 
 Diagnostics 
Hot Spring Hot Tub in Protection Mode? 
Try a hard reset. Switch the power off, wait 2 minutes then switch back on.  
If the above does not work, suggests an issue with the Hi-Limit Sensor. 
 
Hot Spring Hot Tub Stuck on 10 degrees and won't heat 
Try a hard reset. Switch the power off, wait 2 minutes then switch back on.  
If the above does not work, suggests an issue with the Hi-Limit Sensor. 
 
Hot Spring Hot Tub Ready and Power Lights Flashing 
Check the screen for further diagnostics, may suggest one of the above issues? 
Try a hard reset. Switch the power off, wait 2 minutes then switch back on.  
If the above does not work, suggests an issue with the Hi-Limit Sensor. 
 
Hot Spring Logo Light Flashing 
Check the screen for further diagnostics, may suggest one of the above issues? 
Try a hard reset. Switch the power off, wait 2 minutes then switch back on.  
If the above does not work, suggests an issue with the Hi-Limit Sensor.